Cogo di ka funteni sɛgɛsɛgɛli yɔrɔ min bɛ a yɛrɛ ma, o saniya ka ɲɛ?

Oct 31, 2025 Aw bɛ cikan bila .

 

 

 

Tiɲɛ na, ni a ye otomatiki dafalen ye .Sumaya-falen-falen-yɔrɔ .walima masinw ka minɛn wɛrɛw, saniya ye ladonni yɔrɔ nafamaba ye.Sɛnɛfɛnw saniyacogo min tɛ kɔlɔsi, o tɛ dan minɛnw sanfɛla saniya ma.Full automatique heat exchangeur .Unit fana ka kan ka saniya.A ka c’a la, nin fɛɛrɛ saba bɛ kɛ ni PLC ye min bɛ funteni ɲɔgɔn falen-falenni kɛ a yɛrɛma.

 

countrecurrent flushing method:A bɛ kɛ caman na baara kɛtuma na walima waati kunkurunnin kɔnɔ{0}}waati la, wa minɛn in mago tɛ ka wuli.Nka, a bɛ kɛ cogo o cogo, a bɛ kɛ ka tɛmɛ ni sira ye min bɛ kɛ ka tɛmɛ, o ka kan ka kɛ pre-Installed on the Equipment ye.O fɛɛrɛ nafa ka bon ni scaling ma juguya.

 

High-Tressure ji jet flushing method:Ji marifa kunkolo minnu bɛ wuli ka wuli, olu bɛ se ka sugandi funtenifalenfalen suguya wɛrɛw kama; U bɛ se ka kɛ fɛn gɛlɛnw ye.A bɛ se ka wuli fana, ni degun bɛ se ka ladilan hɔrɔnya la ka bɔ 10MPa la ka se 200mpa ma.High-Tressure Water Cleaning bɛnnen don ka saniya pibilikiw ni ɲɔgɔn cɛ, pipew kɔnɔ, ani bɔgɔdaga kɔnɔ. High-Tpressure Water Jets bɛ baara kɛ ka ɲɛ ani u bɛ kɛ ka caya walasa ka funteni falenfɛnw wuli.

 

Furakɛli kɛcogo: Aw bɛ ji nɛnɛma don ani ka bɔ kondensalɛri la, ka sɔrɔ ka funteni jateminɛnan, tansiyɔn jateminɛnan, walima jibolisiraw kɛ ka anti-nɔgɔ ɲagamilan ni ɲɔgɔn cɛ walasa ka joli-sira-funu-minɛn fitinin dɔ dilan.First, add the pickling corrosion inhibitor. Nin fura in ye kuran sɔgɔlilan kɛrɛnkɛrɛnnen ye. A bɛ nɔrɔ kondensalɛri kɔnɔna kogo la walasa ka asidi bali ka kɛ ni nɛgɛ ye.Asidi solide saniyalan bɛ kɛ ka limescale saniya, o min bɛ kɛ kɛrɛnkɛrɛnnenya la ni karisiyɔmu karɔbɔni ye.Sanuyalan ye asidi biologiki gɛlɛn gɛlɛn ye, min ye kristalɛ finman ye, min tɛ ni nɛgɛw ye minnu tɛ tiɲɛ Saniyalan min bɛ kɛ, o hakɛ bɛ bɔ a hakɛ la min bɛ kɛ ka sɛgɛsɛgɛli kɛ minɛnw kan.Add a scale remover (a bɛ se ka kɛ). Ni kondensalɛri ka sɛgɛsɛgɛli ka bon, sɛgɛsɛgɛlikɛlan ka kan ka fara a kan.A bɛ fɛnw wuli joona ka bɔ u la minnu bɛ sɔrɔ sɛgɛsɛgɛli kɛcogo la ji la, o bɛ kɛ sababu ye ka sɛgɛsɛgɛli juguman kɛ.A bɛ asidi tolen neutralize ni fɛn min bɛ kɛ ka fɛn dɔ kɛ, o bɛ kɛ sababu ye ka a ka asidi tolen neutraliser condensateur saniya kɔfɛ, ka oksidan bali ka kɛ nɛgɛ ye ani ka ruti filanan kɛ.

 

O la, mɔgɔ dɔw bɛ se k’a ɲininka, funteni sɛgɛsɛgɛlikɛlan dafalen ka kan ka saniya siɲɛ joli? actually,The cleaning cycle for intelligent heat exchange units is not fixed.Factors such as the℃of scaling in the heat exchanger, equipment operating conditions, heat exchange efficiency, and production water consumption need to be considered comprehensively.Generally, if the equipment operates stably and the heat exchange efficiency does not decrease significantly, it can be cleaned every six months to a year.If a decrease in heat exchange efficiency or significant scaling is detected, cleaning is necessary in advance.In industrial production, heating heat exchange units are Baarakɛminɛnw bɛ to ka baara kɛ, o la, u ka kan ka sɛgɛsɛgɛ ani ka saniya tuma bɛɛ walasa u ka baara kɛcogo ɲuman ani u ka funteni ɲɔgɔn falen-falen.

N’i ​​b’a fɛ ka kunnafoni wɛrɛw sɔrɔ Heat Exchanger units kan walima n’i b’a fɛ ka sanni kɛ, i ka email ci 9988xiaoshuai@gmail.com ma, an bɛna i jaabi waati kɔnɔ cikan yelen kɔfɛ!